A09614 Summary:
BILL NO | A09614A |
  | |
SAME AS | SAME AS S07669 |
  | |
SPONSOR | Lupardo |
  | |
COSPNSR | Mosley, Steck, Crouch, Cahill, Blake, Robinson, Solages |
  | |
MLTSPNSR | Cook, Glick, Hooper, Lupinacci, Magee, Nolan, Palmesano |
  | |
Amd §§378 & 372, Exec L | |
  | |
Relates to standards for the inspections of parking structures. |
A09614 Actions:
BILL NO | A09614A | |||||||||||||||||||||||||||||||||||||||||||||||||
  | ||||||||||||||||||||||||||||||||||||||||||||||||||
03/22/2016 | referred to governmental operations | |||||||||||||||||||||||||||||||||||||||||||||||||
05/05/2016 | amend (t) and recommit to governmental operations | |||||||||||||||||||||||||||||||||||||||||||||||||
05/05/2016 | print number 9614a | |||||||||||||||||||||||||||||||||||||||||||||||||
05/10/2016 | reported referred to ways and means | |||||||||||||||||||||||||||||||||||||||||||||||||
05/25/2016 | reported | |||||||||||||||||||||||||||||||||||||||||||||||||
05/26/2016 | advanced to third reading cal.827 | |||||||||||||||||||||||||||||||||||||||||||||||||
06/06/2016 | passed assembly | |||||||||||||||||||||||||||||||||||||||||||||||||
06/06/2016 | delivered to senate | |||||||||||||||||||||||||||||||||||||||||||||||||
06/06/2016 | REFERRED TO HOUSING, CONSTRUCTION AND COMMUNITY DEVELOPMENT | |||||||||||||||||||||||||||||||||||||||||||||||||
06/16/2016 | SUBSTITUTED FOR S7669 | |||||||||||||||||||||||||||||||||||||||||||||||||
06/16/2016 | 3RD READING CAL.1356 | |||||||||||||||||||||||||||||||||||||||||||||||||
06/16/2016 | PASSED SENATE | |||||||||||||||||||||||||||||||||||||||||||||||||
06/16/2016 | RETURNED TO ASSEMBLY | |||||||||||||||||||||||||||||||||||||||||||||||||
11/16/2016 | delivered to governor | |||||||||||||||||||||||||||||||||||||||||||||||||
11/28/2016 | vetoed memo.250 | |||||||||||||||||||||||||||||||||||||||||||||||||
11/28/2016 | tabled |
A09614 Committee Votes:
Farrell | Aye | Oaks | Aye | ||||||
Lentol | Aye | Crouch | Aye | ||||||
Schimminger | Excused | Barclay | Aye | ||||||
Gantt | Aye | Fitzpatrick | Nay | ||||||
Weinstein | Aye | Saladino | Aye | ||||||
Glick | Aye | Hawley | Aye | ||||||
Nolan | Aye | Duprey | Aye | ||||||
Pretlow | Aye | Corwin | Aye | ||||||
Perry | Aye | Malliotakis | Aye | ||||||
Colton | Aye | Walter | Aye | ||||||
Cook | Aye | ||||||||
Cahill | Aye | ||||||||
Aubry | Aye | ||||||||
Hooper | Aye | ||||||||
Thiele | Aye | ||||||||
Wright | Aye | ||||||||
Cusick | Aye | ||||||||
Ortiz | Aye | ||||||||
Benedetto | Aye | ||||||||
Markey | Aye | ||||||||
Moya | Aye | ||||||||
Weprin | Aye | ||||||||
Rodriguez | Aye | ||||||||
Ramos | Aye | ||||||||
Braunstein | Aye | ||||||||
Go to top
A09614 Floor Votes:
Yes
Abbate
Yes
Crespo
Yes
Gottfried
Yes
Lopez
Yes
Palumbo
Yes
Simon
Yes
Abinanti
Yes
Crouch
Yes
Graf
Yes
Lupardo
Yes
Paulin
Yes
Simotas
Yes
Arroyo
Yes
Curran
Yes
Gunther
Yes
Lupinacci
Yes
Peoples-Stokes
Yes
Skartados
Yes
Aubry
Yes
Cusick
Yes
Harris
Yes
Magee
Yes
Perry
Yes
Skoufis
Yes
Barclay
Yes
Cymbrowitz
Yes
Hawley
ER
Magnarelli
Yes
Pichardo
Yes
Solages
Yes
Barrett
ER
Davila
Yes
Hevesi
Yes
Malliotakis
Yes
Pretlow
Yes
Stec
Yes
Barron
ER
DenDekker
Yes
Hikind
Yes
Markey
Yes
Quart
Yes
Steck
Yes
Benedetto
Yes
Dilan
Yes
Hooper
Yes
Mayer
Yes
Ra
Yes
Stirpe
Yes
Bichotte
Yes
Dinowitz
Yes
Hunter
Yes
McDonald
Yes
Raia
Yes
Tedisco
ER
Blake
ER
DiPietro
Yes
Hyndman
Yes
McDonough
ER
Ramos
Yes
Tenney
Yes
Blankenbush
Yes
Duprey
Yes
Jaffee
Yes
McKevitt
Yes
Richardson
Yes
Thiele
Yes
Brabenec
Yes
Englebright
Yes
Jean-Pierre
Yes
McLaughlin
Yes
Rivera
Yes
Titone
Yes
Braunstein
Yes
Fahy
Yes
Johns
Yes
Miller
Yes
Robinson
ER
Titus
ER
Brennan
Yes
Farrell
Yes
Joyner
Yes
Montesano
Yes
Rodriguez
Yes
Walker
Yes
Brindisi
Yes
Finch
ER
Katz
Yes
Morelle
Yes
Rosenthal
Yes
Walter
Yes
Bronson
Yes
Fitzpatrick
Yes
Kavanagh
Yes
Mosley
Yes
Rozic
Yes
Weinstein
Yes
Buchwald
Yes
Friend
Yes
Kearns
Yes
Moya
Yes
Russell
Yes
Weprin
Yes
Butler
Yes
Galef
ER
Kim
Yes
Murray
Yes
Ryan
Yes
Williams
Yes
Cahill
Yes
Gantt
Yes
Kolb
Yes
Nojay
Yes
Saladino
Yes
Woerner
Yes
Cancel
Yes
Garbarino
Yes
Lalor
Yes
Nolan
Yes
Santabarbara
ER
Wozniak
Yes
Castorina
Yes
Giglio
Yes
Lavine
Yes
Oaks
ER
Schimel
ER
Wright
Yes
Ceretto
Yes
Gjonaj
Yes
Lawrence
Yes
O'Donnell
Yes
Schimminger
Yes
Zebrowski
Yes
Colton
ER
Glick
Yes
Lentol
ER
Ortiz
Yes
Seawright
Yes
Mr. Speaker
Yes
Cook
Yes
Goldfeder
Yes
Lifton
Yes
Otis
ER
Sepulveda
ER
Corwin
Yes
Goodell
ER
Linares
Yes
Palmesano
Yes
Simanowitz
‡ Indicates voting via videoconference
A09614 Text:
Go to top STATE OF NEW YORK ________________________________________________________________________ 9614--A IN ASSEMBLY March 22, 2016 ___________ Introduced by M. of A. LUPARDO, MOSLEY, STECK, CROUCH, CAHILL, BLAKE -- Multi-Sponsored by -- M. of A. COOK, GLICK, LUPINACCI, MAGEE, NOLAN -- read once and referred to the Committee on Governmental Operations -- committee discharged, bill amended, ordered reprinted as amended and recommitted to said committee AN ACT to amend the executive law, in relation to standards for inspections of parking structures The People of the State of New York, represented in Senate and Assem- bly, do enact as follows: 1 Section 1. Section 378 of the executive law is amended by adding a new 2 subdivision 17 to read as follows: 3 17. Standards for inspections of parking structures requiring: 4 a. periodic inspections of parking structures at least once every five 5 years and inspections where the structural integrity of a parking struc- 6 ture is or has been compromised by a storm, flood, collision, accident 7 or other natural or manmade occurrence, or where a parking structure has 8 known deficiencies. Such inspections shall: 9 (i) include a structural integrity evaluation of the structural and 10 foundation systems, which shall include an analysis of: 11 (1) to the extent practicable, the design, design as-built plans, and 12 structural alterations or maintenance repairs that have been made; 13 (2) code changes since the time of original design; 14 (3) the live load capacity rating in accordance with accepted engi- 15 neering practices; and 16 (4) any deterioration of or modification to the original structure; 17 (ii) include a ten year life cycle projection, to estimate the scope 18 and cost of maintenance, repair and rehabilitation in order to provide 19 comprehensive parking structure safety; 20 (iii) include a review of the most recent inspection report; 21 (iv) be performed by a licensed professional engineer who shall meet 22 the qualifications for parking structure design, construction or 23 inspection experience as prescribed by the council; EXPLANATION--Matter in italics (underscored) is new; matter in brackets [] is old law to be omitted. LBD14663-04-6A. 9614--A 2 1 (v) include a rating based on a rating system established by the coun- 2 cil that reflects the structural integrity and safety of the parking 3 structure; 4 (vi) be reported on forms prescribed by the council, subscribed by the 5 inspecting engineer and filed with the council within sixty days of the 6 completion of the inspection; 7 (vii) be made available to the public; 8 b. maintenance guidelines for parking structures; 9 c. guidelines for the conspicuous posting of a parking structure's 10 live load capacity rating; 11 d. procedures for the temporary closing of an unsafe parking struc- 12 ture; and 13 e. submission to the council of reasonably available past parking 14 structure inspection reports. 15 § 2. Section 372 of the executive law is amended by adding a new 16 subdivision 20 to read as follows: 17 20. "Parking structure" means any building or structure, or part ther- 18 eof, in which a structural level other than a slab on grade is used for 19 parking or storage of motor vehicles. 20 § 3. This act shall take effect on the ninetieth day after it shall 21 have become a law.